CAV® 4.1
9725-D35
CAV® 4.1 Single-Bath Benchtop Kinematic Viscometer
The CAV 4.1 replaces CANNON's trusted, obsolete CAV-2100 viscometer.
In stock
9725-D35
CAV® 4.1 Single-Bath Benchtop Kinematic Viscometer
The CAV 4.1 replaces CANNON's trusted, obsolete CAV-2100 viscometer.
In stock
CANNON® CAV® 4.1 is a fully automated, single bath, benchtop viscometer with two 14-position sample handlers for unattended D445 processing. Each of the two tubes covers a 100-fold viscosity range at values between 0.5 mm2/s (cSt) and 10,000 mm2/s (cSt) from 40 °C to 150 °C (down to 20 °C with optional integral bath cooler).
The CAV 4.1 replaces CANNON's trusted, obsolete CAV-2100 viscometer.
Conforms to ASTM D445/446. Common applications include formulated oil analysis, hydraulic oil analysis, additive analysis, marine fuel testing, base stock analysis, light and heavy fuel testing, waxes/paraffin, crude oil testing, and glycols/polyols.
Viscometer Tube Configuration Information
Protect your investment and ensure your instrument continues to provide quality and reliable results for years to come with a CANNON Service Plan.
Factory installation of this unit is required. If factory installation is waived, only parts are covered during the warranty period. Damage occurring from incorrect installation is not covered by warranty.
*Some upper viscosity measurements may be limited by test temperature and sample type. Ubbelohde-style tubes (for volatile products that are not a pure solvent and high melt waxes) are also available in 100-fold increments and fast run 10-fold increments from 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt).
Unit Weight | 54 kg (130 lb) |
---|---|
Method | ASTM D445/D446, IP 71, ISO 3104/3105, SAE J300 |
Dimensions (W x D x H) | 36.0 cm × 66.0 cm × 72.0 cm (14.3 in × 26.0 in × 28.5 in) |
Shipping Dimensions (W x D x H) | 81.3 cm × 53.3 cm × 99.0 cm (32.0 in × 21.0 in × 39.0 in) |
Shipping Weight (With All Items) | 96.6 kg (213.0 lb) |
Maximum Throughput | 24 tests per hour |
Sample Capacity | 28 (2 x 14 positions), automated |
Viscosity Range | 0.5 mm²/s (cSt) to 10,000 mm²/s (cSt) in 100-fold increments (depending on viscometer tube selection). Fast run tubes are also available. |
Timing Resolution | 0.01 s (timing accuracy to ± 0.001 s) |
Temperature Range and Accuracy | 40 °C to 100 °C,± 0.01 °C (down to 20 °C with cooling option) |
Minimum Sample/Solvent Volume | 8 mL sample (as little as 3 mL with fast run tubes)/15 mL solvent per test |
Operating Conditions | 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), Installation Category II; Pollution Degree 2 |
Electrical Specifications | 100 Vac, 50/60 Hz; 115 Vac, 50/60 Hz; 230 Vac, 50/60 Hz; 1200 watts power consumption |
Compliance | CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc, 60 sec.); ROHS |
Data Output | USB |