Downloads

CANNON suggests using Windows® 10 operating system. Any computers running Windows® XP must download the appropriate XP software in the notes section of the instrument or program. Please address all questions to customer service at 814-353-8000 or 800-676-6232. Refer to the Computer Specifications information that is included in the instrument documentation. 

 

Software Files

ZIP Files

Version

Released

Notes

BBRw

1.35.1

 10/07/2021

Software required for running ASTM D6648 and AASHTO T313 tests using the BBR.

For Windows® XP software, click BBRw XP (version 1.27).

BBRw Long Test Version

3.24

 

NOT INTENDED FOR PRODUCTION USE. Software for special extended loading time and recovery time. Intended for research.

FlowHub™

2310.1.0

 10/16/2023

 

HTHS

2.02

 

 

SPS

1.33

05/02/22

 

TESC D2983 Testing

 

 

 

TESC D5133 Testing

2404.1.0

coming soon

 

TESC D8210 Testing

 

 

 

VISCPRO I

1.32.3

1/24/2023

For Windows® XP software, click VISCPRO I XP (version 1.31.8).

VISCPRO II

2.73.1

09/12/2024

VISCPRO must always be as up-to-date as the CAV 4.2 software. VISCPRO can be newer than the CAV 4.2 software, but if the software on the CAV 4.2 is newer, there could be some compatibility issues. Update VISCPRO to avoid issues.

For Windows® XP software, click VISCPRO II XP (version 2.56.4).

Network Setup Script for using VISCPRO II with CAV 4.2

 

4/29/2016

This script can be used to automatically perform the Set up network adapter and Configure firewall rules procedures on pages 28-31 or the CAV 4.2 Operator's Manual.

 

 

VISCPRO II

 

  CAV 4.2/4.1 Package

2.73.1

1.39.1

 

E_CAV4200UI.EXE/

E_CAV4100UI.EXE

 

   Firmware Package

1.39

2.0.28

Bath Controller

Sample Handler

Valve Controller

2.0.8

0.55

0.11

 

Firmware

ZIP Files

Version

Released

Notes

Firmload for Windows 

 

 

 

BBR

 

 

Firmware for the TE-BBR 

BBR-SD

2.10

6/29/2021

Firmware for the BBR-SD

AV2100

1.05

 

Latest version of the AV2100

Contains SlavTalk and AV Sensor

AV2200

2.09

 

Latest version of the AV2200

miniAV

2.35

 

Latest version of the miniAV

Must be used with VISCPRO II version 2.56.3 and newer.

Now uses % Overdraw

  • Fast run: Bulb 1 = 100%, Bulb 2 = 40% 
  • Standard Run: Bulb 1 = 50%, Bulb 2 = 10%
CAV 4.2 UI/Firmware 
CAV 4.1 UI/Firmware

1.39.1

09/12/2024

Must update to latest version of Viscpro II when updating instrument firmware.

 

When the sample handler is updated to firmware .21:
  • DO NOT HOME until adjusting the elevation offset. Doing so can damage the sample handler
  • Use Teraterm to set both the elevation offfset and heater arm offset to zero
  • With a vial in place, raise the lift bucket
  • Adjust the elevation offset to allow some spring movement in the lift bucket in the raised position
  • Verify that the rotational offset is still ideal. Adjust if necessary
  • Do not adjust the heater arm offset
USB 2.0 to Ethernet Driver

 

 

Drivers to manually install the USB to Ethernet adapter

UltraVIS

2405.1.0

06/04/2024

Updating from pre-version 2302.1.0 will require resetting C/E constants and temperature offset.

CCS

2.17

 

Latest version of CCS. Contains firmware for CCS legacy encoder (version 2.01)

MRV

2.06

 

Latest version of the MRV

CT2K0105

1.05

05/09/2022

 

MFV101

 

 

 

DPV

2.12

2/23/2021

Contains DPV firmware version 2.12 for chilled applications.

Contains DPV firmware version 2.11 for unchilled applications.

PolyVISC

2.16

 

Latest version of the PolyVISC

TE3K0103

 

 

 

LubeVIS

0112

 

 

PulpVIS

0112

 

 

SimpleVIS

0112

 

 

SimpleVIS II

0112