TE-BBR SD

Sku#

9728-V31

TE-BBR SD Thermoelectric Bending Beam Rheometer



In stock

The TE-BBR SD is a thermoelectrically-cooled bending beam rheometer for testing flexural creep of asphalt binders from ambient to –40 °C (±0.03 °C). A crack seal option provides for low temperature characterization of crack seal “creep” under load for 0.5” thick specimens.

The TE-BBR SD meets or exceeds ASTM, AASHTO, and SHRP provisions for flexural creep testing of asphalt binders, including ASTM D6648, AASHTO T 313, SHRP Binder Provisions.

Common applications include flexural creep of asphalt binders and low temperature characterization of crack seal under load.

Protect your investment and ensure your instrument continues to provide quality and reliable results for years to come with a CANNON Service Plan.

 

Precise, Repeatable Results

  • Meets or exceeds ASTM, AASHTO, and SHRP requirement for low temperature flexural creep testing of asphalt binders including ASTM D6648 and AASHTO T 313
  • Instrument sample supports feature specimen support strips 3 mm ±0.30 mm in top radius
  • Temperature range: ambient to −40 °C.
  • Temperature stability: ±0.03 °C with resolution to ±0.01 °C.
  • Resolves specimen beam deflection to 0.155 µm (1550 Å)
  • Resolves force to within 0.147 mN (0.015 g)

Reliable and Versatile Performance

  • Instruments installed and in operation in asphalt testing labs throughout the world
  • Performance verified through ASTM round-robin testing
  • Pneumatic pressure regulators allow operator to adjust pressure on main input line, air bearing, and load shaft support
  • Capable of measuring specimen beam loads from 0 g to 500 g
  • Instrument provided with factory-calibration in an ISO 9001-registered laboratory
  • Digital thermometer and probe included with instrument purchase, along with a one year warranty

Simple, Automated Testing

  • Easy-to-use Windows®-based operational software (included) controls the entire testing process and provides a visual display of stress and strain
  • Simple data transfer via USB interface
  • Reports and graphs can be printed on any Windows compatible printer

Compact, self-contained unit

  • TE-cooled with solid-state Peltier elements. Requires no pressurized coolants (a separate air-water heat exchanger is included) and is environmentally friendly
  • An integrated, self-contained bath cools using methanol or ethanol as the bath medium
Specifications
Unit Weight

Control Unit: 49.9 kg (110 lb)
Load Unit: 15.9 kg (35 lb)
Air/Water Heat Exchanger: 68.0 kg (150 lb)

Method ASTM D6648, AASHTO T 313
Dimensions (W x D x H)

Control Unit: 73.7 cm × 71.1 cm × 55.9 cm (29 in × 28 in × 22 in)*
Load Unit: 58.4 cm × 48.3 cm × 68.6 cm (23 in × 19 in × 27 in)
Air/Water Heat Exchanger: 49.5 cm × 40.6 cm × 48.3 cm (19.5 in × 16 in × 19 in)
* add 15 cm (6 in) to front and rear dimensions for connection and airflow allowance

Shipping Dimensions (W x D x H)

Control & Load Units: 101.6 cm × 81.3 cm × 121.9 cm (40 in × 32 in × 48 in)
Air/Water Heat Exchanger: 61.0 cm × 53.3 cm × 66.0 cm (24 in × 21 in × 26 in)

Shipping Weight (With All Items) 136.4 kg (300 lb)
Maximum Throughput 6 results per hour
Sample Capacity 1
Temperature Range and Accuracy Ambient to −40 °C (±0.03 °C stability; ±0.01 °C resolution)
Operating Conditions 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), Installation Category II, Pollution Degree 2
Electrical Specifications 120 Vac, 50/60 Hz; 240 Vac, 50/60 Hz; 1800 watts power consumption
Compliance CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc, 60 sec.); ROHS
Data Output USB
Flexural Creep stiffness Range 20 MPa to 1 Gpa
Sample Supports Specimen supports strips 3 mm ±0.30 mm in top radius
Bath Volume 5 L (1.33 gal)
Sample Dimensions 12.7 mm × 6.35 mm × 127 mm (0.5 in × 0.25 in × 5 in)