miniAV®-LT

Sku#

9725-A94

miniAV®-LT Single-Bath Sub-Zero Kinematic Viscometer

In stock

This is non stock item.

CANNON miniAV-LT is a fully automated, single sample, benchtop viscometer for low temperature (sub-zero) viscosity testing. A Ubbelohde-style tube covers a viscosity range from 5-50 cSt at ‒20 °C and ‒40 °C.

Complies with methods ASTM D445/D446, ASTM D1655, DEF STAN 91:91, IP71, ISO 3104/3105.

Common application: Natural Petroleum and Synthetic Jet fuel

Factory installation of this unit is required. If factory installation is waived, only parts are covered during the warranty period.  Damage occurring from incorrect installation is not covered by warranty.

D445 precision in a compact, robust design

  • Temperature testing at −20 °C and −40 °C
  • Viscosity range: 5-50 cST
  • Fits in roughly the same bench-top area as an analytical balance
  • A well-tested CANNON viscometer platform offers reliability and dependable support

Fully automated bench-top testing and reduced consumable costs

  • Affordable alternative to labor-intensive manual KV testing
  • VISCPRO® PC software enables one computer to manage and control up to four instruments
  • Automated vial washing & drying reduces vial consumption and replaces manual washing
  • ASTM D446/ISO 3105 Ubbelohde-style tube reduces solvent usage and disposal costs by 50%

Simplified maintenance & test versatility

  • Modular bath for easy maintenance access
  • Operators physically replace tubes in minutes, eliminating the need for service calls
  • Single-point temperature calibration avoids tube recalibration costs and maximizes test flexibility
  • Standard dual solvent input
Specifications
Unit Weight

Unit: 27 kg (45 lb)
Power Supply: 11 kg (24 lb)
Waste Receiver: 6 kg (13 lb)
Air/Water Heat Exchanger: 14 kg (30 lb)
Chiller: 23 kg (50.72 lb)

Method ASTM D445/D446, ASTM D1655, DEF STAN 91:91, IP 71, ISO 3104/3105
Dimensions (W x D x H)

Unit: 25.4 cm × 30.5 cm × 53.4 cm (10 in × 12 in × 21 in)
Power Supply: 34.3 cm × 39.6 cm × 17.2 cm (13.5 in × 15.6 in × 6.8 in)
Waste Receiver: 33.0 cm × 39.6 cm × 17.2 cm (13.0 in × 15.6 in × 6.8 in)
Air/Water Heat Exchanger: 38.6 cm × 51.1 cm × 34.9 cm (15.2 in × 20.1 in × 13.7 in)
Chiller: 225 mm × 360 mm × 380mm (8.86 in × 14.17 in × 14.96 in)

Shipping Dimensions (W x D x H)

Box 1: 73.7 cm × 63.5 cm × 94.0 cm (29 in × 25 in × 37 in)
Box 2: 76.2 cm × 58.4 cm × 83.8 cm (30 in × 23 in × 33 in)
Box 3: 15.2 cm × 15.2 cm × 28.0 cm (6 in × 6 in × 11 in)

Shipping Weight (With All Items) 98.9 kg (218 lb)
Maximum Throughput 1 test per hour
Sample Capacity 1
Viscosity Range 5-50 cSt
Timing Resolution 0.01 s (timing accuracy to ± 0.001 s)
Temperature Range and Accuracy −20 °C and −40 °C ± 0.02 °C
Minimum Sample/Solvent Volume 5 mL sample/15 mL solvent per test
Operating Conditions 15 °C to 30 °C, 10% to 75% relative humidity (non-condensing), Installation Category II; Pollution Degree 2
Electrical Specifications 100 Vac, 50/60 Hz; 115 Vac, 50/60 Hz; 230 Vac, 50/60 Hz; 1000 watts power consumption
Compliance CE Mark; EMC directive (2004/108/EC); Low voltage directive (2006/95/EC); HI-POT (1900 Vdc, 60 sec.); ROHS
Data Output RS-232 via RS-485