General KV Viscosity Table
Nominal kinematic viscosity values of general purpose viscosity standards in mm2/s (cSt)
This table presents nominal data. Actual values, provided with each standard, may vary slightly from lot to lot and formulations are subject to change. If your application requires close conformity with published nominal values, please contact technical service to obtain the actual viscosity values associated with the current formulation.
Catalog Number |
Viscosity Standard |
−40 °C |
−20 °C |
20 °C |
25 °C |
37.78 °C |
40 °C |
50 °C |
60 °C |
80 °C |
98.89 °C |
100 °C |
SUS |
SUS |
SFS |
9727-C10 |
N.4† |
— |
— |
0.47 |
0.45 |
0.41 |
0.40 |
— |
— |
— |
— |
— |
— |
— |
— |
9727-C15 |
N.8† |
— |
— |
0.74 |
0.70 |
0.61 |
0.60 |
— |
— |
— |
— |
— |
— |
— |
— |
9727-C20 |
N1.0† |
— |
2.5 |
1.3 |
1.2 |
1.0 |
0.97 |
0.91 |
— |
— |
— |
— |
— |
— |
— |
9727-C22 |
N2 |
— |
— |
2.9 |
2.6 |
2.1 |
2.0 |
1.7 |
— |
1.1 |
0.95 |
0.93 |
— |
— |
— |
9727-C25 |
S3 |
80 |
— |
4.6 |
4.0 |
3.0 |
2.9 |
2.4 |
— |
1.5 |
1.2 |
1.2 |
— |
— |
— |
9727-C27 |
N4 |
— |
— |
6.7 |
5.8 |
4.2 |
4.0 |
3.2 |
— |
1.9 |
1.5 |
1.5 |
— |
— |
— |
9727-C30 |
S6 |
— |
— |
11 |
8.9 |
6.0 |
5.7 |
44 |
— |
2.4 |
1.8 |
1.8 |
— |
— |
— |
9727-C31 |
N7.5 |
— |
— |
14 |
12 |
8.0 |
7.5 |
5.8 |
— |
3.1 |
2.3 |
2.3 |
— |
— |
— |
9727-C32 |
N10 |
— |
— |
21 |
17 |
11 |
10 |
7.3 |
— |
3.5 |
2.5 |
2.4 |
— |
— |
— |
9727-C34 |
N14 |
1700 |
— |
30 |
25 |
15 |
14 |
10 |
— |
5.0 |
3.5 |
3.4 |
— |
— |
— |
9727-C35 |
S20 |
— |
— |
44 |
34 |
20 |
18 |
13 |
— |
5.6 |
3.9 |
3.8 |
100 |
— |
— |
9727-C36 |
N26 |
— |
— |
57 |
46 |
27 |
25 |
18 |
— |
7.9 |
5.3 |
5.2 |
130 |
— |
— |
9727-C37 |
N35 |
— |
— |
87 |
66 |
35 |
32 |
21 |
— |
8.5 |
5.4 |
5.3 |
170 |
— |
— |
9727-C38 |
N44 |
— |
— |
110 |
86 |
48 |
44 |
30 |
— |
12 |
7.7 |
7.5 |
220 |
— |
— |
9727-C40 |
S60 |
— |
— |
160 |
120 |
60 |
54 |
35 |
— |
12 |
7.7 |
7.5 |
280 |
— |
— |
9727-C41 |
N75 |
— |
— |
200 |
150 |
82 |
75 |
50 |
— |
19 |
12 |
12 |
380 |
— |
— |
9727-C42 |
N100 |
— |
— |
330 |
230 |
110 |
97 |
60 |
— |
19 |
11 |
11 |
500 |
— |
— |
9727-C43 |
N140 |
— |
— |
400 |
300 |
160 |
140 |
90 |
— |
31 |
19 |
18 |
720 |
— |
— |
9727-C45 |
S200 |
— |
— |
550 |
410 |
200 |
180 |
120 |
— |
40 |
24 |
23 |
950 |
112 |
— |
9727-C46 |
N250 |
— |
— |
770 |
570 |
280 |
250 |
160 |
— |
51 |
30 |
29 |
1300 |
140 |
— |
9727-C47 |
N350 |
— |
— |
970 |
710 |
350 |
310 |
190 |
— |
60 |
34 |
32 |
1620 |
160 |
— |
9727-C48 |
N415 |
— |
— |
1400 |
990 |
470 |
420 |
250 |
— |
77 |
43 |
41 |
2180 |
200 |
— |
9727-C50 |
S600 |
— |
— |
1740 |
1200 |
600 |
520 |
300 |
— |
92 |
50 |
49 |
— |
240 |
150 |
9727-C51 |
N750 |
— |
— |
2600 |
1900 |
850 |
750 |
440 |
— |
130 |
68 |
66 |
— |
— |
— |
9727-C52 |
N1000 |
— |
— |
3400 |
2400 |
— |
940 |
550 |
350 |
150 |
— |
80 |
— |
— |
— |
9727-C53 |
N1400 |
— |
— |
5100 |
3600 |
— |
1400 |
820 |
510 |
220 |
— |
120 |
— |
— |
— |
9727-C55 |
S2000 |
— |
— |
8300 |
5300 |
1900 |
1600 |
800 |
— |
160 |
75 |
72 |
— |
360 |
— |
9727-C56 |
N2500 |
— |
— |
10400 |
7000 |
— |
2500 |
1300 |
750 |
290 |
— |
140 |
— |
— |
— |
9727-C57 |
N4000 |
— |
— |
20000 |
12000 |
— |
3400 |
1600 |
850 |
290 |
— |
120 |
— |
— |
— |
9727-C58 |
N5100 |
— |
— |
28000 |
18000 |
— |
5100 |
2500 |
1300 |
420 |
— |
170 |
— |
— |
— |
9727-C60 |
S8000 |
— |
— |
41000 |
25000 |
8000 |
6700 |
3200 |
— |
530 |
— |
215 |
— |
— |
— |
9727-C61 |
N10200 |
— |
— |
58000 |
36000 |
— |
10200 |
4900 |
2500 |
775 |
— |
300 |
— |
— |
— |
9727-C62 |
N15000 |
— |
— |
77000 |
47000 |
— |
13000 |
6100 |
3000 |
980 |
— |
360 |
— |
— |
— |
9727-C63 |
N18000 |
— |
— |
103000 |
64000 |
— |
18000 |
8500 |
4300 |
1320 |
— |
500 |
— |
— |
— |
9727-C65 |
S30000 |
— |
— |
— |
79000 |
27000 |
22000 |
11000 |
— |
1700 |
— |
630 |
— |
— |
— |
† Incurs additional shipping charges due to low flash point